Bug reports

Occasionally we find bugs in the current release of Venom2 or VenomIDE which may affect users. Usually a 'workaround' is possible. Bug reports and any workarounds applying to recent releases are documented on this page.

Bug reports for older releases of Venom2 are documented in the Release Notes.

Bug report for Venom 2

Release 2012-05-09 (Current)

SymptomExplanation, Workaround and Fix
printf () conversion errors with
printf("%-0nd", ...) (where n is a number)
and with e.g.
printf("%+07.3f",0.0)
Identified bugs in printf() conversion functions
Workaround: None
Fix: In the next release
In previous versions: Yes

Bug report for VenomIDE

This section lists known bugs in the current release of VenomIDE.

Release 1.5.0.81 (current)

SymptomExplanation, Workaround and Fix
Mouse wheel doesn't scrollSometimes the mouse wheel fails to scroll through the text in an edit window.
Workaround: Clicking on an edit file tab corrects this.
Fix: None.
In previous versions: Yes
Find: Whole words onlyThe 'Whole words only flag' isn't always applied to the 'Find in flies option'.
Workaround: None.
Fix:
In previous versions: Yes
Terminal takes focus from Find dialogueWhen characters come into the terminal the Find dialogue loses focus
Workaround: Stop the VM2 sending text to the terminal while using Find.
Fix:
In previous versions: Yes
Terminal window problemsThe Venom command line cursor can sometimes disappear off the bottom of the Terminal window; in Windows 7 the Terminal window can sometimes aquire two vertical scrollbars.
Workaround: Left-dock the Terminal window.
Fix:
In previous versions: Yes

Release 1.5.0.80

SymptomExplanation, Workaround and Fix
File tabs disappearIf you have a Project open, and close one or more project files then some of the file tabs may disappear.
Workaround: Don't close files within a project, only open and close whole projects.
Fix: In next version.
In previous versions: No

Bug report for Windows relating to VenomIDE

There are some bugs, or features, in Windows that can prevent VenomIDE working correctly.
SymptomExplanation, Workaround and Fix
Help not displayingSome Windows configurations may not display the .CHM Help files supplied with VenomIDE.
Workaround: Any Windows .CHM (Compiled HTML) application must be installed on a local drive (i.e. typically drive C: or D:), as a Microsoft Windows security problem prohibits its use on a network drive.
Fix: None
In previous versions: n/a
Error message on starting VenomIDEA Microsoft Windows XP security update in 2007 caused trouble with a number of applications including the Micro-Robotics IDE.
Workaround: None
Fix: If an error message pops up when you start the IDE, see if it matches that shown on Microsoft knowledge base article 935448 and if so, apply the fix suggested on that page. For other error messages or if that doesn't work, please email techsupport@microrobotics.co.uk with full text of the error message, and any other details such as which Windows version you are using, and we'll investigate.
In previous versions: No
 